Near Miss Miami-Dade Fire Rescue

Views: 207

Add a Comment

You need to be a member of My Firefighter Nation to add comments!

Join My Firefighter Nation

Comment by FETC on June 12, 2009 at 10:09pm
I have to applogize but after watching this "training video" for 16 minutes I have more questions than answers.

Was this a malfunction of the SCBA equipment or human error for not donning his mask properly that caused the original leak? He admits having a leak, going back downstairs to re-don the mask but then mentions using his bypass valve, obtaining better visability but was this for obtaining additional air to the mask (no air @ regulator failure) or was this because he clearly admits to "smelling smoke" with his mask on?

Ultimately it ends quickly with a mention of partially turned on main valve, and he hit the wall and turned it off? That explains the reason for a rapid (totally empty cylinder) but that doesn't explain the air leak, smell of smoke, use of by-pass, etc.

The training division addressed the NFA - LUNAR, but I have to question if you have a solid mayday SOG with hands on training for when your firefighters should declare a mayday. If not then it is time to have an in-house procedure not just the NFA's recommendation.

Another thought, especially after learning so much from the brothers in Providence. Was Lt. True just treated for CO or was his blood gasses drawn for HCN exposure. Watching the video, knowing what furnishings are in a modern home of today, the likelihood is the HCN exposure was missed due to its 1/2 life being so short.

The video pretty much didn't address all the issues that occurred to Lt. True and his SCBA problems.

Last question, was his SCBA sent out to be tested by the manufacturer and flow tested to confirm or deny the equipment was working properly? May I suggest: obtaining some grant money for real, NFPA 2007 compliant SCBA's with buddy breathing and EBSS connections so no one will ever have to suck a mask when a partner standing right next to you could be sharing air without ever having to doff a mask to take a blow? HCN is today's bread and butter firefighter killer and unfortunately in only a short "few" breaths - Lt. True was very lucky on this one.

TCSS
Comment by Aaron Robbins on June 11, 2009 at 4:32pm
yea what the heck...
Comment by Ricky Dale Maddox on June 11, 2009 at 10:47am
Okay wait , you had a leak in you mask and didnt realize you was low on airr after you had a major leak?? Wow!! When ya have a leak in a mask get out dont stay in!!